Brochure NRS 1.41 Mo

NRS-3100 Raman Spectrometer

NRS-3100 is the entry-level instrument without the low wave number measurement, high resolution option, and dichroic mirrors. This compact and simplified cost-effective system is well suited to educational and routine QC analysis, especially when samples to be measured are already specified. The NRS-3100 shares a automated optical system and sophisticated user friendly software with higher class models in this series.

Advanced Features and Options

  •       • High quality on-screen sample viewing and image capture or trinocular (binoculars + camera port) option
  •       • Software controlled dichroic mirrors and beam splitters
  •       • Spectral range from Visible through NIR
  •       • 50 cm-1 - 80,000 cm-1 measurement range (Raman shift at 532nm excitation)
  •       • One to three automated holographic gratings
  •       •&nbFully kinematic six position Rayleigh rejection filters
  •       • Fiber optic remote for in-situ measurements
  •       • Up to two internal solid state lasers with software switched optics for up to six separate laser sources
  •       • Auto alignment of laser optical path
  •       • Open microscope that provides access and a 120 degree motorized sample chamber door
  •       • Class 1 laser safety with full laser interlock
  •       • Supplie KnowItAll informatics System, JASCO Edition including reference database of 600 spectra

Specifications

Resolution: 1 cm-1
Optional laser wavelength range : Visible - NIR
Wavenumber range (Raman shift at 532 nm excitation): 50 to 8000 cm-1
CCD detector : 1024 x 128 pixel CCD air-cooled to -65 degree celsius

NRS-3200 Raman Spectrometer


With the higher specification CCD detector (air-cooled to -75 degree celsius) than it of NRS-3100, NRS-3200 has greater flexibility including excitation wavelength selection, beam splitter configuration, and automatic filters switching mechanism, This system can be applicable to any kind of advanced research analysis. Additionally, the NRS-3200 provides the optional ability to perform Raman imaging.


Advanced Features and Options

  •       • High quality on-screen sample viewing and image capture or trinocular (binoculars + camera port) option
  •       • Software controlled dichroic mirrors and beam splitters
  •       • Spectral range from deep UV through NIR
  •       • 50 cm-1 - 80,000 cm-1 measurement range (Raman shift at 532nm excitation)
  •       • One to three automated holographic gratings
  •       • Fully kinematic six position Rayleigh rejection filters
  •       • Fiber optic remote for in-situ measurements
  •       • Direct Raman imaging system option
  •       • Up to two internal solid state lasers with software switched optics for up to six separate laser sources
  •       • Auto alignment of laser optical path
  •       • Open microscope that provides access and a 120 degree motorized sample chamber door
  •       • Class 1 laser safety with full laser interlock
  •       • Supplie KnowItAll informatics System, JASCO Edition including reference database of 600 spectra

Specifications

Resolution: 1 cm-1 (0.4 cm-1 optional)
Optional laser wavelength range : UV-NIR
Wavenumber range (Raman shift at 532 nm excitation): 50 to 8000 cm-1
CCD detector : 1024 x 128 pixel CCD air-cooled to -75 degree celsius
Raman imaging optional

NRS-3300 Raman Spectrometer

The high-end flagship of our all-new series, the NRS-3300 offers many innovative and powerful feature you expect in a research grade Raman system, including kinematically mounted filters, a powerful confocal microscope and ultra-high performance CCD detector and laser are included. Added to this are a high-resolution capability, a unique ultra-low wave number attachment allowing measurement from 10 cm-1 and the ability to switch effortlessly between up to two internal and four external lasers, including gas, UV and NIR types.

Advanced Features and Options

  •       • High quality on-screen sample viewing and image capture or trinocular (binoculars + camera port) option
  •       • Software controlled dichroic mirrors and beam splitters
  •       • Spectral range from deep UV through NIR
  •       • 10 cm-1 - 80,000 cm-1 measurement range option
  •       • One to three automated holographic gratings
  •       • Fully kinematic six position Rayleigh rejection filters
  •       • Fiber optic remote for in-situ measurements
  •       • Direct Raman imaging system option
  •       • Up to two internal solid state lasers with software switched optics for up to six separate laser sources
  •       • Auto alignment of laser optical path
  •       • Open microscope that provides access and a 120 degree motorized sample chamber door
  •       • Class 1 laser safety with full laser interlock
  •       • Supplie KnowItAll informatics System, JASCO Edition including reference database of 600 spectra

Specifications

Resolution: 1 cm-1 (0.4 cm-1 optional)
Optional laser wavelength range : UV-NIR
Laser/Raman beam splitter : Dichroic mirrors and beam splitter
Wavenumber range (Raman shift at 532 nm excitation): 50 to 8000 cm-1 (10 to 8000 cm-1 with Low wavenumber attachment)
CCD detector : 1024 x 128 pixel CCD air-cooled to -75 degree celsius
Raman imaging optional

 

 


     Zone de la Bouvre, 17 rue Gutenberg 44340 BOUGUENAIS      Tel: +33(0)2.40.43.00.43    Fax: +33(0)2.40.43.24.37