La gamme de produits d’extraction Cleanert a été conçue pour simplifier et améliorer vos préparations d’échantillons en combinant supports, formats et méthodologies appropriées. Ces produits utilisent différents types de supports (Silices nues ou greffées, Polymères,Fluorisil, Carbone…) pour préparer tous types d’échantillons. Les cartouches Cleanert présentent une grande pureté, stabilité ainsi qu’une excellente reproductibilité.
Avec les produits Cleanert vous bénéficirez de méthodes SPE robustes sans devoir craindre l’obtention de résultats non reproductibles ni de faibles rendements.
Silice greffée
Cleanert ODS C18
ODS C18 cartridges and plates are packed with reversed phase, octadecylsilane
bonded silica sorbents. The sorbent is double endcapped and has a high bonding
density (%C>17). These cartridges can be used as a replacement for BondElute C18
and Super clean ENVI C18. These products can be used for desalting biomolecules,
such as proteins and DNAs.
- Based on silica; C%: 18-19%
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 480²/g.
Cleanert ODS C18-N
ODS C18-N products have silica based reverse phase sorbents bonded with
octadecylsilane without endcapping. The extra silanol residue of the sorbent
provides additional polar interactions associated with surface silanol
groups which enhance the retention of basic compounds. These columns are
similar to Agilent AccuBond C18 and BondElute C18 OH.
- Based on silica; C%: 17-18%
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 480²/g
Cleanert C8
The property of C8 products is similar to ODS C18 products. However,
this sorbent is slightly less retentive than C18, which facilitates the elution
of more hydrophobic substance. C8 is successfully used for the extraction of both
water-soluble and fat-soluble vitamins from serum, as well as the desalting of biological
macromolecules.
- Based on silica; C%: 9-10%
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 480²/g
Cleanert CN
Cleanert CN(cyano-)SPE cartridge is cyanopropyl-boned-silica based extraction cartridge.
This cartridge is with medium polarity, and can be used for reversed phase or normal phase
extraction.
Cleanert NH2
NH2 SPE products have silica based sorbents bonded with aminopropyl funtional group.
This sorbent can be used in either normal phase or reverse phase mode. It retains the
analytes either by a polar adsorption (from non-polar solution) or by weak anion exchange
(from aqueous solution). pKa=9.8 .
- Based on silica
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 480m²/g
Cleanert COOH
COOH SPE products consist of a propane carboxylic acid on the inner silica surface.
The pKa of the carboxylic acid group is approximately 3.8. It is a useful sorbent for
quaternary ammonium salt and other strong cations.
- Based on silica; C%: 5-6%
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 4802/g
Cleanert Silica
Silica SPE product has unbonded, activated irregular silica as the sorbent.
This sorbent exhibits high polar interaction and is used for the extraction of
weak-polar or non-polar compound, such as oil. In addition, the silanol groups
are ionzable at intermediate pH, so it can be used as a weak cation exchanger.
- Based on silica;
- Average particle diameter: 50µm;
- Average pore size: 60Å;
- Volume of pore: 0.8cm2/g;
- Specific surface area: 4802/g
Cleanert PSA
PSA SPE is similar to Cleanert-NH2. PSA has two amino groups with pKa=10.1
and 10.9 respectively. This sorbent is an anion exchanger slightly stronger
than NH2. It can be used for the extraction of metal ions by chelating interactions.
It is also commonly used to remove organic acids, pigments and metal ions from organic
samples such as vegetables and fruits.
- Based on silica
- Average particle diameter: 50µm
- Average pore size: 60Å
- Volume of pore: 0.8cm²/g
- Specific surface area: 480²/g
Cleanert PRS
PRS SPE sorbent is a silica gel based strong cation exchanger. This sorbent,
consisting of a propane sulfonic acid, has slightly less exchange capability than SCX.
It can be applied to the extraction of weak cations, such as pyridine, with high recovery.
- Based on silica;
- Average particle diameter: 50µm;
- Average pore size: 60Å;
- Volume of pore: 0.8cm2/g;
- Specific surface area: 480m2/g
- The ion exchange degree: 0.3meq/g.
Cleanert SCX
SCX products are strong cation exchangers based on silica gel, with benzene
sulfonic acid. The sorbent is used to extract positively charged basic compounds
or remove the salt from biological samples. It can also be mixed with C18 sorbent
to extract the organic bases.
- Based on silica;
- Average particle diameter: 50µm;
- Average pore size: 60Å;
- Volume of pore: 0.8cm2/g; Specific surface area: 480m2/g
- The ion exchange degree: 0.5meq/g.
Cleanert SAX
SAX SPE products have silica based sorbents bonded with a quaternary amine. This strong
anion exchanger is used to extract compounds capable of carrying a negative charge from both
aqueous and non-aqueous solutions. They are ideally suit to extraction of weak acids and desalting
of biological macromolecules, like BondElute-SAX.
- Based on silica; C%: 9-10%;
- Average particle diameter: 50µm;
- Average pore size: 60Å;
- Volume of pore: 0.8cm2/g;
- Specific surface area: 480m2/g
- The ion exchange degree: 0.5meq/g.
Cleanert Diol
Silica based dihydroxy SPE. It is used to extract polar analytes from non-polar solutions.
It is a neutral sorbent and extracts compounds by forming hydrogen bonding or polar-polar
interaction. As an example, it can be used to extract THC.
- Based on silica; C%: 5-6%;
- Average particle diameter: 50µm;
- Average pore size: 60Å;
- Volume of pore: 0.8cm2/g;
- Specific surface area: 4802/g
Sorbent | Vol. | Tubes/box | ODS C18 (end capping) | ODS C18 (without end capping) | C8 | CN | NH2 | PSA |
---|---|---|---|---|---|---|---|---|
100mg | 1ml | 100 | 181001 | 181001-N | 081001 | CN1001 | NH1001 | PA1001 |
200mg | 3ml | 50 | 182003 | 182003-N | 082003 | CN2003 | NH2003 | PA2003 |
500mg | 3ml | 50 | 185006 | 185006-N | 085006 | CN5006 | NH5006 | PA5006 |
500mg | 6ml | 30 | 180006 | 180006-N | 080006 | CNOO06 | NHOO06 | PAOO06 |
1g | 6ml | 30 | 180100 | 180100-N | 080100 | CN0100 | NH0100 | PAO 1 00 |
50mg/well | 2ml | 30 | 180502-W | 180502-N-W | 080502-W | CN0502-W | NH0502-W | PA0502-W |
100mg/well | 2ml | 30 | 181002-W | 181002-N-W | 081002-W | CN1002-W | NH1002-W | PA1002-W |
10g | 180010 | 180010-N | 80010 | CN0010 | NH0010 | PA0010 | ||
100g | 180100 | 1810100-N | 80100 | CN0100 | NH0100 | PA0100 |
Sorbent | Vol. | Tubes/box | SAX | COOH | PRS | SCX | Silica | Diol |
---|---|---|---|---|---|---|---|---|
100mg | 1ml | 100 | SA1001 | CH1001 | PR1001 | 8C1001 | 811001 | 010501 |
200mg | 3ml | 50 | SA2003 | CH2003 | PR2003 | 8C2003 | 812003 | 011001 |
500mg | 3ml | 50 | SAS006 | CH5006 | PR5006 | 8C5006 | 815006 | 015006 |
500mg | 6ml | 30 | SAOO06 | CHOO06 | PROO06 | 8COO06 | 810006 | 010006 |
1g | 6ml | 30 | SA0100 | CH0100 | PR0100 | 8C0100 | 810100 | 010100 |
50mg/well | 2ml | 30 | SA0502-W | CH0502-W | PR0502-W | 8C0502-W | 810502-W | 010502-W |
100mg/well | 2ml | 30 | SA1002-W | CH1002-W | PR1002-W | 8C1002-W | 811002-W | 011002-W |
10g | SA0010 | CH0010 | PR0010 | SC0010 | SI0010 | DI0010 | ||
100g | SA0100 | CH0100 | PR0100 | SC0100 | SI0100 | DI0100 |
Support d'absorption sans silice
Cleanert Alumina A
Cleanert Alumina A is acidic alumina SPE cartridge, the pH of which is 4.5.
It can be used as strong polar adsorbent and medium cation exchanger. The special
deactivation of this cartridge makes sure the reproducibility of samples.
Cleanert Alumina B
Alumina B products(pH=10) can be used to remove organic acids and phenols in the
sample matrix. They have been pre-treated by special deactivation to ensure high
analytes recovery.
- Adsorption sorbents
- Average particle size: 150 mesh
- Average pore size: 58Å
Cleanert Alumina N
Alumina N sorbents(pH=7.5) can adsorb molecules by interaction with the aluminum
metal center. The neutralized surface allows interaction with compounds whose heteroatoms
are electronegative(e.g.N,S,P) or with an electron-rich ,highly aromatic structure.
- Adsorption sorbents
- Average particle size: 150 mesh
- Average pore size: 58Å
Cleanert Pesticarb
PestiCarb is made of graphitized carbon by a distinct surface modifcation process, and has been
used for sample cleanup in pesticide residues in plants or animal tissues. This sorbent can effectively
reduce the background noise and increase the sensitivity, the functions of which are similar to Supelco
Envicarb.
- Adsorption sorbents
- Average particle size: 120-400 mesh.
Sorbent | Vol. | Tubes/box | Florisil | PestiCarb | Alumina N | Alumina A | Alumina B |
---|---|---|---|---|---|---|---|
100mg | 1ml | 100 | FS1001 | PC1001 | AL1001-N | AL1001-A | AL1001-B |
200mg | 3ml | 50 | FS2003 | PC2506 | AL2003-N | AL2003-A | AL2003-B |
500mg | 3ml | 50 | FS5006 | PC5006 | AL5006-N | AL5006-A | AL5006-B |
500mg | 6ml | 30 | FS0006 | PCOO010 | AL0006-N | ALOO06-A | AL0006-B |
1g | 6ml | 30 | FS0100 | PC200010 | ALOIOO-N | AL0100-A | AL0100-B |
50mg/well | 2ml | 30 | FS0502-W | PC0502-W | AL0502-N-W | AL0502-A-W | AL0502-B-W |
100mg/well | 2ml | 30 | FS1002-W | PC1002-W | AL1002-N-W | AL1002-A-W | AL1002-B-W |
10g | FS0010 | PC0010 | AL0010-N | AL0010-A | AL0010-B | ||
100g | FS0100 | PC0100 | AL0100-N | AL0100-A | AL0100-B |
Polymères
Cleanert PEP
PEP is made of polydivinylbenzene on which the surface is functionalized with vinyl prolidone.
The material has a balanced hydrophilic and hydrophobic property and can be used in the entire
pH range of 1-14.
- Functionalized polymer sorbents
- Average particle size: 35µm or 70µm.
- Average pore size: 80Å
- Surface area: 600m2/g.
Cleanert PEP-2
Cleanert PEP-2(Polar Enhanced Polymer)is functional polystyrene/divinylbenzene SPE cartridge. The surface
is bonded with hydrophilic and hydrophobic functional groups simultaneously. So this cartridge has equivalent
adsorption interaction with polar or non-polar compounds. The applicable pH range is 1.0-14.0. It is equivalent
to Waters Oasis HLB.
Cleanert PEP-H
PEP-H is one of the series of PEP.
It is base on the polydivinylbenzene and derived from PEP by increase the surface polarity
to improve the adsorption for polar analytes
The material can be used in the entire pH range of 1-14, also can be used to extract a variety
of polar and non-polar compounds. Some highly hydrophilic compounds
which have little retention on C18 columns
- Functionalized polymer sorbents
- Average particle size: 70µm.
- Average pore size: 80Å
- Surface area: 600m2/g
Cleanert PCX
Cleanert PCX is water-wettable polymer based SPE cartridge, which
depends on cation exchange mixed mechanism. It is stable in the pH range
of 0-14.0. In addition, this cartridge has high binding capacity. It is widely
used for extraction and purification of basic compounds from biological matrices,
which need high adsorption capacity, such as plasma, urine, bile, tissue homogenate.
It is equivalent to Waters Oasis MCX.
Cleanert PAX
It is designed to overcome the limitations of traditional silica based mixed-mode SPE sorbents such
as C18/SAX. It is a RP/strong anionexchange mixed mode polystyrene/divinylbenzene sorbent, stable
from pH 0-14.0 .
- Based on functioalized polystyrene/divinylbenzene
- Average particle diameter: 40µm
- Average pore size: 70Å
- Volume of pore: 1.2cm2/g
- Specific surface area: 6002/g
Cleanert PWCX
Cleanert PWCX provides the dual modes of retention, weak cation exchange and reverse
phase on a stable polymer sorbent, which improves the retention for basic analytes.
- Based on partially functionalized polystyrene/divinylbenzene;
- Average particle diameter: 40µm
- Average pore size: 70Å
- Volume of pore: 1.2cm2/g
- Specific surface area: 6002/g.
Cleanert PWAX
Cleanert PWAX provides the dual modes of retention, weak anion exchange and
reverse phase on a stable polymer sorbent, which improves the retention for
acidic analytes.
- Based on partially functionalized aminopolystyrene/divinylbenzene
- Average particle diameter: 40µm
- Average pore size: 70Å
- Volume of pore: 1.2cm2/g
- Specific surface area: 6002/g.
Cleanert PS
PS is made of non-substituted polydivinylbenzene. It has larger surface areas (>600m2/g.) and thus greater capacity
than reverse phase bonded silica.PS can be used for the extraction of non-polar and polar compounds.
- Based on polystyrene/divinylbenzene
- Average particle diameter: 40µm
- Average pore size: 70Å
- Volume of pore: 1.2cm2/g
- Specific surface area: 6002/g.
Sorbent | Vol. | Particle Size | Tubes/box | PEP | PEP-2 | PEP-H | PAX | PCX | PWAX | PWCX | PS |
---|---|---|---|---|---|---|---|---|---|---|---|
30mg | 1ml | 35µm | 100 | PE0301-S | |||||||
60mg | 3ml | 35µm | 50 | PE0603-S | |||||||
30mg | 1ml | 70µm | 100 | PE0301 | PE0301-2 | PE0301-H | AX0301 | CX0301 | WA0301 | WC0301 | PS0301 |
60mg | 3ml | 70µm | 50 | PE0603 | PE0603-2 | PE0603-H | AX0601 | CX0601 | WA0603 | WC0603 | PS0601 |
100mg | 3ml | 70µm | 50 | PE1003 | PE1003-2 | PE1003-H | AX0603 | CX0603 | WA1003 | WC1003 | PS0603 |
200mg | 6ml | 70µm | 30 | PE2006 | PE2006-2 | PE2006-H | AX1506 | CX1506 | WA2006 | WC2006 | PSI508 |
500mg | 6ml | 70µm | 30 | PE5006 | PE5006-2 | PE5006-H | AX5006 | CX5006 | WA5006 | WC5006 | PS5008 |
30mg/well | 2ml | 70µm | 96-wellplate | PE0302-W | PE0302-2W | PE0302-HW | AX0302-W | CX0302-W | WA0302-W | WC0302-W | PSQ302-W |
50mg/well | 2ml | 70µm | 96-wellplate | PE0502-W | PE0502-2W | PE0502-HW | AX0502-W | CX0502-W | WA0502-W | WCOOO2-W | PSQ502-W |
10g | 70µm | PE0010 | PE0010-2 | PE0010-H | AX0010 | CX0010 | WAOOIO | WCOOI0 | PSOO10 | ||
100g | 70µm | PE0100 | PE0100-2 | PE0100-H | AX0100 | CX0100 | WA0100 | WC0100 | PS0100 | ||
30mg/well | 2ml | 35µm | 96-wellplate | PE0302-SW | |||||||
50mg/well | 2ml | 35µm | 96-wellplate | PE0502-SW | |||||||
10g | 35µm | PE0010-S | |||||||||
100g | 35µm | PE0100-S |
Phases spéciales
Cleanert HXH
HXN is also made of polydivinylbenzene having surface modified with vinylpyrrolidone.
This sorbent is specially designed to extract sulfonyl ureas from water and soil at ppb level.
It is less polar than PEP and can also be used to extract, enrich and clean up samples from
mid polar to high polar compounds.
- Based on polystyrene/divinylbenzene;
- Average particle diameter: 40µm;
- Average pore size: 70Å;
- Volume of pore: 1.2cm2/g;
- Specific surface area: 6002/g
Sorbent | Vol. | Tubes/box | HXN |
---|---|---|---|
30mg | 1mL | 100 | HX0301 |
60mg | 3mL | 50 | HX0603 |
100mg | 3mL | 50 | HX1003 |
200mg | 6mL | 30 | HX2006 |
500mg | 6mL | 30 | HX5006 |
30mg/well | 2mL | 96w | HX0302-W |
50mg/well | 2mL | 96w | HX0502-W |
10g | HX0010 | ||
100g | HX0100 |
Cleanert SUL-5
Specific SPE column for Sulfonamides
SUL-5(Specific SPE column for Sulfonamides) is specially designed
for the extraction of five sulfonamides (SM2, SMM,SMZ, SDM, SQ) in p
Sorbent | Vol. | Tubes/box | HXN |
---|---|---|---|
2g | 12ml | 100 | SUL-5 |
Cleanert DNPH-Silica
Specialized for Pretreatment of Aldehydes and Ketones in Air
At least 14 species of aldehydes and ketones compounds can be detected,
including formaldehyde, acetaldehyde, propionaldehyde, acrolein, butyraldehyde,
E aldehyde, isoamyl aldehyde, hexanal, benzaldehyde, o,m,p-methyl Benzaldehyde,
2,5-dimethyl benzaldehyde, acetone, butanone, pentanone, cyclohexanone, acetophenone.
(1) the average background value of technical indicators: = 0.2µg. (As formaldehyde)
Maximum sample volume :> 75µg. (As formaldehyde)
Maximum sample pressure: 0.15MPa.
The recovery:>90%.
(2) Storage conditions: low temperature (4 ?) and from light
Shelf Life: 90 days.
Notice:Use as soon as possible after unpacking.
Sorbent | Vol. | Tubes/box | DNPH |
---|---|---|---|
200mg | 3ml | 1 | DN2003 |
200mg | 1ml | 1 | ICDN2001 |
Cleanert TPH
TPH means triple phase SPE for Herb, and it was constituted by three kinds of materials.
These three kinds of materials using different mechanism of action, focus on the colorants,
organic acid and organic substance, also cosidering different polarity of the interferent,
such as nonpolarity substance, substance with hydroxyl and carboxyl group, also the basic group.
By mixing different materials together, we achieve a better result of clean up, expecially complicated matrix.
TPH is majorly used for extraction and detection of pesticides from ChineseHerb such as Ramulus Mori,
Honeysuckle and the Fruit of Chinese Wolfberry, It can absorb reduce up to 80% interferent and without adsorb
any pesticide residues.
Cleanert TPH has been used in China national standard methods, Determination of 488 Pesticide Residues
and Related Chemicals Residues and 413 Pesticide Residues and Related Chemicals Residues in the Ramulus Mori,
Honeysuckle and the Fruit of Chinese Wolfberry with GS-MS and LC-MS/MS Respectively, Determination of 448 pesticides
and related chemicals residues in tea—LC-MS-MS method. The process mainly containing ACN extraction, Load the
sample on the pre-actived column, and then eluted by ACN- toluene (3+1).
Sorbent | Vol. | Tubes/box | TPH |
---|---|---|---|
1g | 6ml | 30 | TPH0006 |
2g | 12ml | 20 | TPH200010 |
Cleanert TPT
TPT was constituted by three kinds of materials. These three kinds of materials using different
mechanism of action, focus on the colorants, organic acid and tea polyphenols, also cosidering different
polarity of the interferent, such as nonpolarity substance, substance with hydroxyl and carboxyl group,
also the basic group. By mixing different materials together, we achieve a better result of clean up,
expecially complicated matrix. TPT is majorly used for extraction and detection of pesticides from tea
leaf, It can adsorb reduce up to 80% interferent and without adsorbing any pesticide residues.
Sorbent | Vol. | Tubes/box | TPT |
---|---|---|---|
1g | 6ml | 30 | TPT0006 |
2g | 12ml | 20 | TPT200010 |
Cleanert EPH
Cleanert EPH use specially silica as material to separate aliphatic fraction to atomatic fraction
in soil. The column was used in New Jersey Department of Environmental Protection Site Remediation Program,
extractable petroleum hydrocarbons methodology (Version 1.1). The method also can be move onto the SPE working
station of full-automatic (SPE-10 P/N: SPE-10).
Sorbent | Vol. | Tubes/box | EPH |
---|---|---|---|
5g | 25ml | 15 | SI500025-30 |
Cleanert PPP
Protein Precipitation Plate
Cleanert Protein Precipitation Plate product for DMPK research is manufactured
with the reagents of the highest purity. Every lot is subjected to a wide range of
rigorous quality control tests and must confrm to our strict specifcation.The graded
frit design is optimized to efficiently remove most of the interference of plasma
samples without plugging or breakthrough.The 96-well plate design can be accomplished
with most of auto-station, also minimizing sample handling. The plates are compatible
with Agela 96 well vacuum manifold, also can be used in centrifugal machine.
Loading about 50µl plasma sample
- Add 3 times solvents(ACN:Methanol =3:1)as elute solution and shake the plate to help precipitation
- Apply vacuum or centrifuge to get the solution through the plate
Sorbent | Vol. | Tubes/box | Vaccum | Centrifuge |
---|---|---|---|---|
2ml | 96wellplate | 2 | 96CD2025 | 96CD2025-F |
Cleanert LRC
Large Receiver Column
Cleanert LRC was design to load more solvents when SPE process,
specially can by used in little sorbent bed but Large elute solvents.
Sorbents | Vol | Tubes/Box | Cleanert LRC C18 | Cleanert LRC PEP |
---|---|---|---|---|
200mL | 10mL | 20 | L1820010 | |
260 mL | 10mL | 20 | LPE0610 |
Cleanert LDC
Large Disk for water analysis Cartridge
Cleanert LDC use SPE sorbent to concentrated trace chemical substances in environmental samples.
The special cartridge design was suitable for water concentration, and it can replace SPE disk
in most of the analysis.
Meterial | Vol | Tubes/Box | Cat.No |
---|---|---|---|
Cleanert LDC C18 | 100 | 4 | L181500100 |
Cleanert LDC C18 | 100 | 4 | L181500100-N |
Cleanert LDC PEP | 100 | 4 | LPE000100 |
Cleanert LDC PS | 100 | 4 | LPS000100 |
Cleanert LDC SCX | 100 | 4 | LSC1500100 |
Cleanert Glass column
Cleanert Glass column series can reduce the dissolution of the tube material, and so can
be used in environmental analysis, especially the plasticizer and environmental interferent.
Meterial | Vol | Tubes/Box | Cat.No | |
---|---|---|---|---|
C18 glass | 200 mL | 3 mL | 50 | 182003-G |
Cleanert PEP glass | 60mL | 3 mL | 50 | PE0603-G |
Rapid Test Strip
Rapid test strips for the detection of Aflatoxin,Voitoxin,Melamine,Clenbuterol,Ractopamine
in samples,such as milk,milk powder,feed,cheese,biscuit,urine,corn,rice,bean,peanut,wheat,peanut
butter
P/N | Type | Spec. | Sensitivity | Application |
---|---|---|---|---|
BAQ09011 | Melamine | 50 /package | 50ppb/100ppb | milk,milk powder,feed,cheese,biscuit,urine |
BAQ09005 | Aflatoxin B1 | 50 /package | 10ppb | corn,rice,bean,peanut,wheat, feed |
BAQ10001 | Voitoxin | 50 /package | 100ppb | corn,rice,bean,peanut,wheat,feed |
BAQ09001 | Clenbuterol(urine) | 50 /package | 3ppb | swine urine |
BAQ09001-1 | Clenbuterol(tissue) | 50 /package | 1ppb | swine urine,swine liver etc. |
BAQ09002 | Ractopamine(urine) | 50 /package | 3ppb | swine urine |
BAQ09002-1 | Ractopamine(tissue) | 50 /package | 1ppb | swine urine,swine liver etc. |
BAQ09007 | malachite green(water) | 50 /package | 2ppb | water |
BAQ09007-1 | malachite green(tissue) | 50 /package | 2ppb | tissue |
BAQ09003 | chlormycetin | 50 /package | 0.1ppb | honey,milk,seafood,chicken |
Phases mixtes
Cleanert C8/SCX
It is silica based, with mixed C8 and strong cation exchange chemical group. It is widely
used for extraction of basic drugs from urine and blood.
Sorbent | Vol. | Tubes/box | C8/SCX |
---|---|---|---|
50mg | 3ml | 50 | CS0503 |
130mg | 3ml | 50 | CS1303 |
300mg | 3ml | 50 | CS3003 |
500mg | 6ml | 30 | CS5006 |
1g | 6ml | 30 | CS0006 |
50mg/weel | 6ml | 96-wellplate | CS0502-W |
100mg/well | 2ml | 96-wellplate | CS1002-W |
10g | CS0100 | ||
100g | CS0101 |
PestiCarb/NH2
PestiCarb/NH2 SPE column is packed of 500mg PestiCarb and 500mg NH2.It has been used wildly
in analysis of pesticides residue, esp. for the Japanese Positive List System. It can be used
in pesticide residue analysis, coloring matter, fatty acid and hydroxybenzene.
Sorbent | Vol. | Tubes/box | PestiCarb/NH2 |
---|---|---|---|
500mg/500mg | 6ml | 30 | PN0006 |
Phases MAS
MAS-C
Cleanert MAS is a simple sample treatment for bioanalysis which applies multi-function
impurity adsorption to remove as many as interferences. It combines protein precipitation
with SPE method, and achieve a faster and easier approach.
In LC/MS–(MS) bio-analysis, there are many interferences which will cause unsatisfied result,
such as protein, phospholipid, fat and some surfactant. Phospholipid is a main interference cannot
be eliminated enough by PPT, which can cause ion suppression and variation of peak shape and retation time.
Cleanert MAS follows the similar simple procedures of protein precipitation, but has a better efficency
of phospholipid removal.
Compared to traditional methods including liquid-liquid extraction (LLE), solid-phase extraction
(SPE) and protein precipitation (PPT), Cleanert MAS has a better performance on interference removal
and more convenient operation. It’s a better replacement of protein precipitation, also an evolution
of SPE.
Spec. | Application | Package | Part No. |
---|---|---|---|
1mL | SPE cartridges, used for basic and neutral substances extraction in Plasma and biological samples | 100 | MSC-B-0301 |
1mL | 100 | MSC-B-0601 | |
1mL | SPE cartridges, used for acid substances extraction in Plasma and biological samples | 100 | MSC-A-0301 |
1mL | 100 | MSC-A-0601 |
Spec. | Application | Package | Part No. |
---|---|---|---|
30mg/2ml/well | 96 well plate, used for basic and neutral substances extraction in plasma and biological samples. | 2 | MS-B-0302W |
30mg/2ml/well | 96 well plate, used for basic and neutral substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation) | 2 | MS-B-0302W |
30mg/2ml/well | 96 well plate, used for acid substances extraction in plasma and biological samples. | 2 | MS-A-0302W |
30mg/2ml/well | 96 well plate, used for acid substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation). | 2 | MS-A-0302FW |
30mg/2ml/well | 96 well plate, used for weak acid substances extraction in plasma and biological samples. | 2 | MS-WA-0302-W |
30mg/2ml/well | 96 well plate, used for weak acid substances extraction in plasma and biological samples, design with a filter membrane (can be used in centrifugation) | 2 | MS-WA-0302-FW |
MAS-Q
Adsorption of multiple mechanisms for impurity extraction purification method
Through multi-functionalized compound Absorption materials, biological samples will be
absorbed as the main interfere matrix, and strong water-soluble material be remained in the
tested samples solution. so as to achieve the purification and enrichment purposes
The General Method Includes
- Put the samples and reagent in the centrifugal tube at the same
time, vibration extraction and ultrasonic extraction. - Put SPE material in the centrifugal tube to purify the sample
matrix and after centrifuging the analytes was remained in the solution. - Take supernatant for other treatment or direct detection
Sorbent | Vol | Tubes | Description | Cat.No |
---|---|---|---|---|
PAX 500mg, C18 500mg | 50mL | 50 | MS-SPC5001 | |
PAX 200mg , C18 200mg | 50mL | 50 | MS-SPM5001 | |
6g MgSO4(anhydrous), 1.5g NaAc.3H2O | 50mL | 50 | Extraction tube, used in method(NYT-1380-2007), Apply to pesticide detection in the vegetables and fruit matrix | MS-MG5050 |
100mg PSA,100mg C18, 0.3 g MgSO4(anhydrous) | 15mL | 50 | Clean-up tube, used in method(NYT-1380-2007), Apply to pesticide detection in the vegetables and fruit matrix | MS-PA1010 |
6g MgSO4(anhydrous),250mg PestiCarb,500mg NH2 | 50mL | 50 | Apply to pesticide detection in the vegetables and fruit matrix with lots of colorants | MS-PN5050 |
magnesium sulfate 4 g; sodium chloride 1 g; sodium citrate dibasic sesquihydrate 0.5 g,sodium citrate tribasic dihydrate; | 50 | citrate extraction tube,use to extract the pesticides which are not stable in acid or basic solution | MS-NMS5050 | |
MgSO4, 750 mg | 50 mL | 50 | PSA clean-up tube, used in purification of vegetable and fruit matrix | MS-PAMG1550 |
PSA 125 mg | ||||
500mg C18 | 1.5mL | 50 | Get rid of fatty | MS-185050 |
50mg C18, 150mg MgSO4 (anhydrous) | 1.5mL | 100 | Get rid of fatty | MS-180205 |
200mg PAX | 10mL | 100 | Reduce protein and phospholipid(Basic substance) | MS-AX1030 |
50mg PAX | 1.5mL | 100 | MS-AX0230 | |
200mg PCX | 10mL | 100 | Reduce protein and phospholipid(Acid substance) | MS-CX1030 |
50mg PCX | 1.5 mL | 100 | MS-CX0230 | |
200mg PEP | 10mL | 100 | Reduce protein and phospholipid(Natural substance) | MS-PE1020 |
50mg PEP | 2mL | 100 | MS-PE0205 |
Phases IC
The sample preparation is necessary not only for HPLC but also for IC.
The demands for sample preparation of IC led to a development of a new SPE product family,
which we named « Cleanert Pre-IC”, and they can perform excellently for sample preparation of IC thanks to their sorbent of high capacity and a good flow property.
Cat.No | The type of resin | Average particle size | Capacity | Application | Sepcification |
---|---|---|---|---|---|
IC-RP10 | divinylbenzeneresin | 40µm | 300mg/1cccartridge | To remove substances such as aromatic dyes, somearomatic carboxylic acids, hydrocarbons, andsurfactants from sample matrices. | 50 pk |
C-P10 | polyvinylpyrrolidone(PVP) polymer resin | 40µm | 350mg/1cccartridge | To remove the phenolic fraction of humic acids,tannic acids, lignins, anthocyanins, and azodyesfrom samples. | 50 pk |
IC-A10 | 16% cross-linked,styrene-based,anion-exchangeresin in thebicarbonate form. | 40µm | 0.7meq/1cccartridge | To remove anion contaminant and neutralize thestrongly acidic sample solution.To remove high levels of alkaline ear | 50 pk |
IC-H10 | 16% cross-linked, styrene-based, sulfonic acid , cation-exchange resin in the hydrogen form | 40µm | 2.0-2.2meq/1cc cartridge | To remove high levels of alkaline earths and transitionmetals from sample matrices and in the neutralizationof highly alkaline samples such as sodium hydroxideor sodium carbonate. | 50 pk |
IC-Ag10 | 16% cross-linked, styrene-based, sulfonic acid, cation-exchange resin in the silver form. | 40µm | 2.0-2.2meq/1cc cartridge | To remove high levels of alkaline earths and transitionmetals from sample matrices without acidifying thesample. This ensures good recovery of acid labileanalytes such as nitrite. | 50 pk |
IC-Ba10 | styrene-based, sulfonic acid , cation-exchange resin in the barium form. | 40µm | 2.0-2.2meq/1cc cartridge | To remove SO42-.For reproducible, quantitativedeterminations in low-ionic-strength samples, thesecartridges should be activated with a chloride-basedactivating solution. Then the added chloride need tobe removed. | 50 pk |
IC-M10 | iminodiacetate resin in the ammonium form | 40µm | 0.4meq/1cccartridge | To remove transition metals and matrix eliminationof alkali and alkaline earth metals. | 50 pk |
IC-Ag/H10 | It is a layered cartridge that contains IC- Ag resin and IC- H resin. | 50 pk | |||
IC-Ba/Ag/H10 | It is a layered cartridge that contains IC-Ba resin, IC- Ag resin and IC- H resin. | 50 pk |
Phases SLF
Description
Solid supported liquid/liquid Extraction columns and plates use specially treated diatomaceous
earth materials as a solid support for liquid/liquid extractions. Agela can provide different
pH sorbents as customer requirement to make extraction of different properties substance.
This kind of material were often used in clinical analysis, it also can be used to replace
most of the analysis using Liquid/Liquid extraction (LLE).
Particles Characteristics
- Treated diatomiteous earth materials
- Average particle diameter: 20-80 mesh
- pH=7 (acidification material) or 9-10 (alkalization material);
- Capability of water absorption: 0.8-1mL/g;
The General Method Includes
- Load an aqueous sample into the column by gravity or a soft vacuum.
- Apply one or a multiple organic solvents by gravity or well-controlled vacuum.
- Vacuum the organic solution which contains the analyte out from bottom of the columns or plates, collect the solution.
- Concentrate the collected solution.
Benefit
The SPE procedures can be easily automated. It also can be used to replace most
of the analysis using Liquid/Liquid extraction to reduce the solvent usage, even
emulsification phenomenon of LLE
Sorbent | Description | Package | Cat. No. |
---|---|---|---|
Cleanert SLE | 80-20 mesh;pH=6-8 | 1000g/bottle | HC1001000-7 |
Cleanert SLE | 80-20 mesh;pH=9 | 1000g/bottle | HC1001000-9 |
Cleanert SLE | 80-20 mesh;pH=10 | 1000g/bottle | HC1001000-10 |
Sorbent | Vol. | Tubes/box | Special treated diatomite SLE (pH=7) | Special treated diatomite SLE (pH=9) |
---|---|---|---|---|
200mg | 3ml | 50 | HC2003-7 | HC2003-9 |
500mg | 3ml | 50 | HC5003-7 | HC5003-9 |
500mg | 6ml | 30 | HC5006-7 | HC5006-9 |
1g | 6ml | 30 | HC0006-7 | HC0006-9 |
2g | 12ml | 20 | HC200012-7 | HC200012-9 |
4g | 25ml | 15 | HC400025-7 | HC400025-9 |
200mg | 2ml/well | 96-wellplate | HC2002-7W | HC2002-9W |
400mg | 2ml/well | 96-wellplate | HC4002-7W | HC4002-9W |
500mg | 2ml/well | 96-wellplate | HC5002-7W | HC5002-9W |
Accessoires pour SPE
96well plate
Product name | Specification | Quality | Cat.No | |
---|---|---|---|---|
2mL 96w collection plate | 8×12 pores | Square pore and circular bottom | 1 | 96SP2036 |
2mL 96w collection plate | 8×12 pores | Circular pore and bottom | 1 | 96SP2036-Y |
96well silica pad | 8×12 pores | square pore | 96GP2036 |
12/24 Vaccum Manifold for SPE
Term | Specification, Package | Cat. No. |
---|---|---|
Vaccum equipment | 12positions | VM12 |
24positions | VM24 | |
Flow rate adjusting valve | 12 pieces/ package | A81213 |
Diversion needle threading the plate | 12 pieces/ package | A80100 |
Diaphragm vacuume pump | 1 | A01003 |
Positive Pressure SPE of 48 Positions (EZY-P48)
Products Name | Description | Cat. No. |
---|---|---|
Positive pressure SPE of 48 positions |
|
EZY-P48 |
Vaccum Manifold for 96 Well Plate
Term | Description | Cat. No. |
---|---|---|
Negative SPE with high throughput (VM96) |
|
VM96 |
Heightening module | Application for the experiment of little receiving liquid | VM96-001 |
Empty Cartridge and Sieve Plate
Cat.No | Description | Vol | Package |
---|---|---|---|
AZ-IC-1 | IC Empty column | 1ml | 100 |
AZ-IC-1T | IC Empty column (with 2 x 20um Polyethyelene frit) | 1ml | 100 |
AZ-IC-2.5 | IC Empty column | 2.5ml | 100 |
AZ-IC-2.5T | IC Empty column (with 2 x 20um Polyethyelene frit) | 2.5ml | 100 |
AZ001 | SPE Empty column | 1ml | 100 |
AZ003 | SPE Empty column | 3ml | 100 |
AZ006 | SPE Empty column | 6ml | 100 |
AZ010 | SPE Empty column | 10ml | 100 |
AZ012 | SPE Empty column | 12ml | 100 |
AZ030 | SPE Empty column | 30ml | 100 |
AZ060 | SPE Empty column | 60ml | 50 |
AZ150 | SPE Empty column | 150ml | 25 |
LAZ010 | Large Reservoir Capacity SPE column | 10ml | 100 |
AS001-A | SPE 20um Polyethyelene Frit | 1ml | 100 |
AS003-A | SPE 20um Polyethyelene frit | 3ml | 100 |
AS006-A | SPE 20um Polyethyelene frit | 6ml | 100 |
AS010-A | SPE 20um Polyethyelene frit | 10ml | 100 |
AS012-A | SPE 20um Polyethyelene frit | 12ml | 100 |
AS030-A | SPE 20um Polyethyelene frit | 30ml | 100 |
AS060-A | SPE 20um Polyethyelene frit | 60ml | 50 |
AS150-A | SPE 20um Polyethyelene frit | 150ml | 25 |
LAS010-A | Large Reservoir Capacity SPE 20um Polyethyelene frit | 10ml | 100 |
A80115 | SPE adaptor | fit 1,3,6,12ml | 12 |
96SP2036 | Collection plate, square well, round bottom | 8×12well | 24 |
96SP2036-Y | Collection plate, round well,round bottom | 8×12well | 24 |
96GP2036 | 96 well cap mat | 8×12well | 24 |
96CD1025 | 96 well crash and protein precipitate filter plate | 1ml/well | 2 |
96CD2025 | 96 well crash and protein precipitate filter plate (Use Vacuum or Pressure for Elution) | 2ml/well | 2 |
96CD2025-F | 96 well crash and protein precipitate filter plate (Use Centrifugation For Elution) | 2ml/well | 2 |
96CD01 | Crash and protein precipitate filter cartridge 1ml | 1ml | 100 |
Cleanert, la SPE de Qualité !